Every question from the end of every unit, with hints and answers to open. After you check an answer, mark how you did, and come back to the ones you didn’t get.

15 questions

Unit 14 · Electrical Circuits

Answer these questions

14.
  • a.State Kirchhoff’s current law and voltage law.
  • b.Using Kirchhoff’s laws, find the current in the 2 Ω resistor in Figure 14.25.
  • c.Can Kirchhoff’s laws be used for both AC and DC circuits?
Hint

Junction rule: the current in the 2 Ω resistor is i₁ + i₂. Then one loop with each cell.

Answer
  • a.Current law (first law): the algebraic sum of the currents at a junction is zero; the current flowing in equals the current flowing out. Voltage law (second law): round any closed loop, the algebraic sum of the e.m.f.s equals the algebraic sum of the IR drops (ΣV = 0).
  • b.The current down through 2 Ω is i1+i2 i_1 + i_2 .

Left loop (35 V cell, 3 Ω, 2 Ω): 35=3i1+2(i1+i2)⇒5i1+2i2=35 35 = 3i_1 + 2(i_1 + i_2) \Rightarrow 5i_1 + 2i_2 = 35 … (i)
Right loop (40 V cell, 4 Ω, 2 Ω): 40=4i2+2(i1+i2)⇒2i1+6i2=40⇒i1+3i2=20 40 = 4i_2 + 2(i_1 + i_2) \Rightarrow 2i_1 + 6i_2 = 40 \Rightarrow i_1 + 3i_2 = 20 … (ii)
From (ii), i1=20−3i2 i_1 = 20 - 3i_2 ; in (i), 100−15i2+2i2=35 100 - 15i_2 + 2i_2 = 35 , so 13i2=65 13i_2 = 65 , i2=5 i_2 = 5 A and i1=5 i_1 = 5 A.
Current in the 2 Ω resistor: i1+i2=10 A i_1 + i_2 = \mathbf{10\ A} (and the p.d. across it is 20 V).
c. Yes. The laws come from the conservation of charge and of energy, which hold at every instant. In an AC circuit they are applied to the instantaneous currents and voltages (or to the phasors, with impedances in place of resistances), as long as the circuit is small compared with the wavelength of the AC, as every ordinary circuit is.

15.

Figure 14.26 shows a potentiometer with a cell of 2.0 V and internal resistance 0.40 Ω maintaining a potential drop across the resistance wire AB. A standard cell of constant e.m.f. 1.02 V gives the balance point at 67.3 cm of the wire. To make sure very little current is drawn from the standard cell, a very high resistance of 600 kΩ is put in series with it. The standard cell is then replaced by a cell of unknown e.m.f., and the balance point, found the same way, is at 82.3 cm.

  • a.What is the e.m.f. of the unknown cell?
  • b.What is the purpose of the 600 kΩ resistance?
  • c.Is the balance point affected by this high resistance?
  • d.Would the method work if the driver cell had an e.m.f. of 1.0 V instead of 2.0 V?
Answer
  • a.E1.02=82.367.3 \dfrac{E}{1.02} = \dfrac{82.3}{67.3} , so E=1.02×82.367.3=1.25 V E = 1.02 \times \dfrac{82.3}{67.3} = \mathbf{1.25\ V} .
  • b.Away from the balance point, a current flows through the cell and the galvanometer. The 600 kΩ resistance keeps this current tiny, which protects the standard cell (whose e.m.f. stays accurate only if it is never made to give a real current) and the galvanometer.
  • c.No. At the balance point no current flows in the cell’s branch, so there is no p.d. across the 600 kΩ resistance, whatever its value. (It makes the galvanometer less sensitive near balance, so for the final, exact setting it is shorted out by the switch.)
  • d.No. The p.d. across the whole wire would be less than 1.0 V (the internal resistance takes a little), which is less than the e.m.f.s to be measured (1.02 V and 1.25 V). No point on the wire would balance them, and the galvanometer would deflect the same way everywhere. The driver’s e.m.f. must be larger than any e.m.f. measured.
16.

A student sets up a potentiometer circuit as in Figure 14.27.

  • i.State the principle of the potentiometer.
  • ii.What is potential gradient? On what factors does the potential gradient of a potentiometer depend?
  • iii.The student obtains the balance point at 34.5 cm using a standard cell of e.m.f. 1.50 V. The balance length AC for the test cell is 25.00 cm. Calculate the e.m.f. of the test cell.

The textbook’s figure labels the driver cell 1.5 V and the test cell 5 V, so the book’s numbers don’t work: a 1.5 V driver can’t balance a 5 V cell anywhere on the wire, and the 1.50 V standard only near its far end. The figure here leaves those labels out; the question’s own numbers work.

Answer
  • i.When a constant current flows through a wire of uniform cross-section, the potential difference across any length of it is directly proportional to that length: V=kl V = kl .
  • ii.The potential gradient is the fall of potential per unit length along the potentiometer wire, k=V/l k = V/l (in V/m or V/cm). Since k=IρA k = \dfrac{I\rho}{A} , it depends on the current in the wire (and so on the driver cell’s e.m.f. and internal resistance and the rheostat’s setting), the resistivity of the wire’s material and its area of cross-section.
  • iii.E1.50=25.0034.5 \dfrac{E}{1.50} = \dfrac{25.00}{34.5} , so E=1.50×25.0034.5=1.09 V E = 1.50 \times \dfrac{25.00}{34.5} = \mathbf{1.09\ V} .
17.
  • a.State the principle of the potentiometer. Why is a potentiometer also called a voltmeter of infinite resistance?
  • b.In a meter bridge experiment (Figure 14.28), the balance point is at J with l = 20 cm.
  • i.The values of R and X are doubled and then interchanged. Where is the new balance point?
  • ii.If the galvanometer and the battery are interchanged at the balance position, how is the balance point affected?
Answer
  • a.Principle: for a steady current through a uniform wire, the p.d. across any length is proportional to the length, V∝l V \propto l . It is called a voltmeter of infinite resistance because, at the balance point, it draws no current from the cell or circuit it measures, exactly as a voltmeter of infinite resistance would.
  • b.i. At first, RX=2080=14 \dfrac{R}{X} = \dfrac{20}{80} = \dfrac{1}{4} , so X = 4R. Doubled and interchanged, the left gap holds 2X = 8R and the right gap 2R:

8R2R=l′100−l′⇒4(100−l′)=l′⇒l′=80 cm \frac{8R}{2R} = \frac{l'}{100 - l'} \Rightarrow 4(100 - l') = l' \Rightarrow l' = \mathbf{80\ cm}
(Doubling both doesn’t change their ratio; interchanging them turns l into 100 − l.)
ii. It is not affected. The balance condition P/Q=X/R P/Q = X/R is the same condition after the galvanometer and battery are swapped (it can be written P/X = Q/R), so the galvanometer still reads zero with the jockey at the same point.

18.
  • a.State Kirchhoff’s two laws for electrical circuits.
  • b.In the meter bridge of Figure 14.29, the null point is 60 cm from A. When a resistance of 5 Ω is connected in series with S, the null point is at 50 cm from A. Find R and S.
Answer
  • a.First law: the algebraic sum of the currents at any junction is zero (ΣI = 0). Second law: in any closed loop, the algebraic sum of the e.m.f.s equals the algebraic sum of the IR drops (ΣE = ΣIR).
  • b.First balance: RS=6040⇒R=1.5S \dfrac{R}{S} = \dfrac{60}{40} \Rightarrow R = 1.5S … (i)

Second balance: RS+5=5050⇒R=S+5 \dfrac{R}{S + 5} = \dfrac{50}{50} \Rightarrow R = S + 5 … (ii)
So 1.5S=S+5 1.5S = S + 5 , S=10 Ω S = \mathbf{10\ \Omega} and R=15 Ω R = \mathbf{15\ \Omega} .

19.
  • a.The arrangement of a potentiometer circuit for finding the internal resistance r of a cell is shown in Figure 14.14. Derive an expression for the internal resistance of the cell.
  • b.How can you convert a galvanometer into a voltmeter of suitable range?
Answer

a. Let k be the potential gradient of the wire, the same throughout. K₂ open: the cell gives no current at balance, so its e.m.f. is balanced, at length l1 l_1 : E=kl1 E = kl_1 . K₂ closed: the cell drives a current I through the resistance box R; its terminal p.d. V=IR V = IR is balanced at a shorter length l2 l_2 : V=kl2 V = kl_2 . The cell’s current flows through r and R in series, so E=I(R+r) E = I(R + r) , and dividing by V=IR V = IR ,
EV=R+rR⇒r=(EV−1)R=(l1l2−1)R \frac{E}{V} = \frac{R + r}{R} \Rightarrow r = \left(\frac{E}{V} - 1\right)R = \left(\frac{l_1}{l_2} - 1\right)R
b. Connect a high resistance R in series with the galvanometer. If the galvanometer has resistance G and full-scale current Ig, the combination reads V at full scale when V=Ig(G+R) V = I_g(G + R) , so R=VIg−G R = \dfrac{V}{I_g} - G . The scale is then marked in volts (0 to V), and the meter is connected in parallel with whatever it measures.

20.
  • a.What is the principle of the potentiometer?
  • b.Why is the potentiometer preferred to a voltmeter for measuring the e.m.f. of a cell?
  • c.The e.m.f. of a battery is balanced by 75 cm of a potentiometer wire, and the e.m.f. of a standard cell of 1.02 V by 50 cm of it. Calculate the e.m.f. of the battery.
Answer
  • a.When a constant current flows through a wire of uniform cross-section, the potential difference across any part of it is directly proportional to the length of that part (V=kl V = kl ).
  • b.A voltmeter draws current from the cell, so it reads the terminal p.d., E−Ir E - Ir , which is less than the e.m.f. At the potentiometer’s balance point no current is drawn, so the e.m.f. itself is measured; and being a null method, it doesn’t depend on a meter’s calibration.
  • c.E1.02=7550 \dfrac{E}{1.02} = \dfrac{75}{50} , so E=1.02×1.5=1.53 V E = 1.02 \times 1.5 = \mathbf{1.53\ V} .
21.

Kirchhoff’s laws are very useful in solving complicated circuits.

  • a.What is the significance of the first law?
  • b.State and explain the second law with a circuit diagram.
  • c.Apply these laws to find an unknown resistance.
  • d.What is a meter bridge? Name the material used for its wire.
Answer
  • a.The first law expresses the conservation of charge: charge neither collects nor disappears at a junction, so the current flowing in equals the current flowing out. It lets us write the current in one branch in terms of the others, reducing the number of unknowns.
  • b.In any closed loop, the algebraic sum of the e.m.f.s equals the algebraic sum of the IR drops, ∑E=∑IR \sum E = \sum IR . In the loop ABCA of Figure 14.4, traveling A → B → C → A: E1+E2=I1(R1+R2)+I3R3 E_1 + E_2 = I_1(R_1 + R_2) + I_3R_3 . It expresses the conservation of energy: a charge going once round the loop gains from the cells exactly the energy it gives up in the resistors.
  • c.Applied to a Wheatstone bridge (Figure 14.8), with the galvanometer showing no deflection (Ig = 0): the loop ABDA gives I1P=I2X I_1P = I_2X , the loop BCDB gives I3Q=I4R I_3Q = I_4R , and the junctions B and D give I1=I3 I_1 = I_3 , I2=I4 I_2 = I_4 . Dividing, PQ=XR \dfrac{P}{Q} = \dfrac{X}{R} , so the unknown resistance is X=PQR X = \dfrac{P}{Q}R . For example, with P = 10 Ω, Q = 100 Ω and balance at R = 250 Ω, X = 25 Ω.
  • d.A meter bridge (slide wire bridge) is a practical Wheatstone bridge: a 1 m uniform wire on a board with a meter scale, two gaps for a known and an unknown resistance, and a galvanometer joined to a jockey that slides along the wire. At balance, X=l100−lR X = \dfrac{l}{100 - l}R . Its wire is of constantan (or manganin), an alloy of high resistivity whose resistance hardly changes with temperature; the strips are of thick copper.
22.

A student sets up the circuit in Figure 14.30 to measure the e.m.f. of a test cell.

  • a.Explain why he can’t find a balance point, and state the change he must make to get one.
  • b.State how he would recognize the balance point.
  • c.He obtains the balance point at 37.5 cm with a standard cell of e.m.f. 1.50 V, and at 25.0 cm (AB) with the test cell. Calculate the e.m.f. of the test cell.
  • d.He could have used an ordinary voltmeter to measure the test cell’s e.m.f. directly, but he argues that this instrument is more precise. Justify his argument.
Answer
  • a.The test cell is connected the wrong way round: its − terminal is at A, while the driver cell’s + terminal is at A. Then the cell’s e.m.f. and the p.d. along the wire act the same way round the galvanometer’s loop and add, instead of opposing; the current through the meter never becomes zero. He must reverse the test cell, so that its + terminal is joined to A, the same end as the driver cell’s + terminal. (He should also use a center-zero galvanometer rather than a voltmeter to detect the balance, and check that the driver cell’s e.m.f. is larger than the test cell’s.)
  • b.At the balance point the galvanometer (or meter) shows zero deflection, and the deflection is in opposite directions on either side of it.
  • c.E1.50=25.037.5 \dfrac{E}{1.50} = \dfrac{25.0}{37.5} , so E=1.50×25.037.5=1.00 V E = 1.50 \times \dfrac{25.0}{37.5} = \mathbf{1.00\ V} .
  • d.A voltmeter takes a current from the cell and reads its terminal p.d., E−Ir E - Ir , which is less than the e.m.f. At the potentiometer’s balance point no current flows from the cell, so the e.m.f. itself is measured. It is also a null method: it doesn’t depend on the accuracy of a meter’s scale, and a balance length on a long wire can be read to a millimeter.
23.
  • a.Using Kirchhoff’s laws, derive the balance condition of a Wheatstone bridge.
  • b.In Figure 14.31, AB is a uniform wire of resistance 15 Ω and length 1 m. With ε₁ = 2 V and ε₂ = 75 mV, the balance point is 30 cm from A. Calculate R (take ε₁’s internal resistance as negligible).
  • c.Compare the resistances of a milliammeter, an ammeter and a microammeter.
Answer
  • a.In the bridge of Figure 14.8, let I₁, I₃, I₄ and I₂ flow through P, Q, R and X, and Ig through G from B to D. Loop ABDA: −I1P−IgG+I2X=0 -I_1P - I_gG + I_2X = 0 . Loop BCDB: −I3Q+I4R+IgG=0 -I_3Q + I_4R + I_gG = 0 . Junction B: I1=Ig+I3 I_1 = I_g + I_3 ; junction D: I4=Ig+I2 I_4 = I_g + I_2 . At balance, Ig=0 I_g = 0 , so I1P=I2X I_1P = I_2X , I3Q=I4R I_3Q = I_4R , I1=I3 I_1 = I_3 and I2=I4 I_2 = I_4 . Then I1Q=I2R I_1Q = I_2R , and dividing, PQ=XR \dfrac{P}{Q} = \dfrac{X}{R} .
  • b.The p.d. across 30 cm balances 75 mV. The resistance of 30 cm is 0.30×15=4.5 0.30 \times 15 = 4.5 Ω, so the current in the wire is

I=0.075 V4.5 Ω=160 A I = \frac{0.075\ \text{V}}{4.5\ \Omega} = \frac{1}{60}\ \text{A}
This current flows from ε₁ through R and the wire: 2R+15=160 \dfrac{2}{R + 15} = \dfrac{1}{60} , so R+15=120 R + 15 = 120 and R = 105 Ω.
c. An ammeter of smaller range needs a larger shunt (S=IgG/(I−Ig) S = I_gG/(I - I_g) ), and so has a larger resistance. Microammeter > milliammeter > ammeter: the ammeter, with the largest range, has the smallest resistance.

24.
  • a.Find the terminal potential difference across the cell of e.m.f. 12 V in Figure 14.32.
  • b.Explain briefly how a potentiometer can be used to measure the internal resistance of a cell.
  • c.Compare the resistances of a microvoltmeter, a voltmeter and a millivoltmeter.
Hint

All three branches have the same p.d. V between the two junctions. Write each branch’s current in terms of V.

Answer

a. Let V be the potential of the left junction above the right one. Each cell’s current flows out of its + end into the left junction:
I1=12−V2,I2=6−V1,and through R: V4=I1+I2 I_1 = \frac{12 - V}{2}, \qquad I_2 = \frac{6 - V}{1}, \qquad \text{and through } R:\ \frac{V}{4} = I_1 + I_2
V4=6−V2+6−V⇒V(14+12+1)=12⇒V=121.75=6.86 V \frac{V}{4} = 6 - \frac{V}{2} + 6 - V \Rightarrow V\left(\frac14 + \frac12 + 1\right) = 12 \Rightarrow V = \frac{12}{1.75} = 6.86\ \text{V}
The 12 V cell’s terminals are connected across the junctions, so its terminal p.d. is 6.86 V (= 12 − I₁r₁, with I₁ = 2.57 A). The 6 V cell has I2=6−6.86=−0.86 I_2 = 6 - 6.86 = -0.86 A: it is being charged by the 12 V cell.

  • b.Connect the cell (+ terminal to A) through a galvanometer to the jockey, with a resistance box R and key K₂ across it (Figure 14.14). With K₂ open, find the balance length l1 l_1 for its e.m.f.; with K₂ closed, the balance length l2 l_2 for its terminal p.d. Then r=(l1l2−1)R r = \left(\dfrac{l_1}{l_2} - 1\right)R .
  • c.A voltmeter of larger range needs a larger series resistance (R=V/Ig−G R = V/I_g - G ), so it has a larger resistance. Voltmeter > millivoltmeter > microvoltmeter.
25.
  • a.State Kirchhoff’s second law.
  • b.Two batteries, each of e.m.f. 6.0 V and negligible internal resistance, are connected in series with three resistors as in Figure 14.33. Resistor X has resistance 4.0 Ω and resistor Y 1.5 Ω. The resistance R of the variable resistor is changed until the voltmeter reads zero. Calculate i. the current I in the circuit; ii. the resistance R.
Answer
  • a.In any closed loop of a circuit, the sum of the e.m.f.s equals the sum of the potential drops (IR) round the loop; equivalently, the algebraic sum of the changes of potential round the loop is zero.
  • b.i. The voltmeter is across X and the left battery together. It reads zero when the battery’s e.m.f. is exactly used up across X: 6.0−4.0I=0 6.0 - 4.0I = 0 , so I=1.5 A I = \mathbf{1.5\ A} .
  • ii.Round the whole loop: 6.0+6.0=I(4.0+R+1.5) 6.0 + 6.0 = I(4.0 + R + 1.5) , so 12=1.5(5.5+R) 12 = 1.5(5.5 + R) , 5.5+R=8.0 5.5 + R = 8.0 , R = 2.5 Ω.
26.
  • a.State Kirchhoff’s second law.
  • b.An electric heater has two heating wires, X and Y, connected to a supply of e.m.f. 9.0 V and negligible internal resistance, as in Figure 14.34. X has resistance 2.4 Ω and Y 1.2 Ω. A voltmeter is connected across the wires, and a variable resistor adjusts the power in them. The variable resistor is set so that the voltmeter reads 6.0 V.
  • i.Calculate the resistance of the variable resistor.
  • ii.Calculate the power dissipated in wire X.
Answer
  • a.In any closed loop, the algebraic sum of the e.m.f.s equals the algebraic sum of the IR drops.
  • b.i. Currents in the wires: 6.02.4=2.5 \dfrac{6.0}{2.4} = 2.5 A and 6.01.2=5.0 \dfrac{6.0}{1.2} = 5.0 A, so 7.5 A flows through the variable resistor. The p.d. across it is 9.0−6.0=3.0 9.0 - 6.0 = 3.0 V, so R=3.07.5=0.40 Ω R = \dfrac{3.0}{7.5} = \mathbf{0.40\ \Omega} .
  • ii.P=V2RX=6.022.4=15 W P = \dfrac{V^2}{R_X} = \dfrac{6.0^2}{2.4} = \mathbf{15\ W} .
27.
  • a.i. State Kirchhoff’s second law. ii. Kirchhoff’s second law is linked to the conservation of a certain quantity. State it.
  • b.The circuit of Figure 14.35 is used to compare potential differences. The uniform resistance wire XY has length 1.00 m and resistance 4.0 Ω. Cell A has e.m.f. 2.0 V and internal resistance 0.50 Ω, and the current through it is I. Cell B has e.m.f. E and internal resistance r. The current through cell B is made zero when the contact J is adjusted so that XJ is 0.90 m. The variable resistor R is set at 2.5 Ω.
  • i.Apply Kirchhoff’s second law to the circuit CXYDC to find the current I.
  • ii.Calculate the p.d. across the length XJ of the wire.
  • iii.Use your answer to ii. to state the value of E.
  • iv.State why the internal resistance of cell B is not needed to find E.
Answer
  • a.i. Round any closed loop, the sum of the e.m.f.s equals the sum of the IR drops. ii. Energy.
  • b.i. Round CXYDC: 2.0=I(4.0+2.5+0.50)=7.0I 2.0 = I(4.0 + 2.5 + 0.50) = 7.0I , so I=2.07.0=0.29 A I = \dfrac{2.0}{7.0} = \mathbf{0.29\ A} .
  • ii.Resistance of XJ: 0.901.00×4.0=3.6 \dfrac{0.90}{1.00} \times 4.0 = 3.6 Ω. V=IR=0.286×3.6=1.03 V V = IR = 0.286 \times 3.6 = \mathbf{1.03\ V} .
  • iii.With no current in cell B, its e.m.f. equals the p.d. it balances: E = 1.03 V.
  • iv.No current flows through cell B, so there is no p.d. across its internal resistance (Ir=0 Ir = 0 ), whatever r is: the p.d. across its terminals is its e.m.f.
28.
  • a.A metal wire of constant resistance is used in an electric heater. So as not to overload the circuit, the supply voltage to the heater is reduced from 230 V to 220 V. Find the percentage reduction in the heater’s power.
  • b.A uniform wire AB of length 100 cm is connected across a cell of e.m.f. 1.5 V and negligible internal resistance, as in Figure 14.36. An ammeter of internal resistance 5.0 Ω is connected to the end A of the wire and to a contact C that can be moved along it. Find the ammeter reading with C i. at A; ii. at B.
  • c.Using this circuit, the ammeter reading I is recorded for different distances L of C from A; some of the points are plotted in Figure 14.37.
  • i.Plot the points for C at A and at B (your answers to b.).
  • ii.Draw a line of best fit through all the points, and find the ammeter reading with C at the midpoint of the wire.
  • iii.Use your answer to ii. to calculate the p.d. between A and C with C at the midpoint.
  • d.Explain why, although C is at the midpoint of AB, your answer to c.iii is not half the e.m.f. of the cell.
Answer

a. With R constant, P=V2R P = \dfrac{V^2}{R} , so P∝V2 P \propto V^2 :
P1−P2P1=2302−22022302=52 900−48 40052 900=450052 900=0.085=8.5 % \frac{P_1 - P_2}{P_1} = \frac{230^2 - 220^2}{230^2} = \frac{52\,900 - 48\,400}{52\,900} = \frac{4500}{52\,900} = 0.085 = \mathbf{8.5\ \%}

  • b.i. C at A: the ammeter’s two ends are both at A, so there is no p.d. across it: the reading is zero.
  • ii.C at B: the ammeter is connected directly across the cell (in parallel with the whole wire), so the full 1.5 V is across its 5.0 Ω: I=1.55.0=0.30 A I = \dfrac{1.5}{5.0} = \mathbf{0.30\ A} .
  • c.i. and ii. The points (0, 0) and (100 cm, 0.30 A) added, the best-fit line is a gentle curve, bending upwards, through all six points:
L (cm) 0 20 40 50 60 80 100
I (A) 0 0.052 0.097 0.12 0.145 0.207 0.30

(The 50 cm value is read from the curve; the others are the plotted points.)
At the midpoint, L = 50 cm, the reading is 0.12 A.

  • iii.V=IR=0.12×5.0=0.60 V V = IR = 0.12 \times 5.0 = \mathbf{0.60\ V} .
  • d.The ammeter takes a current, and it is connected in parallel with the part AC of the wire. So the current through AC is less than the current through CB: AC and the ammeter together have a smaller resistance than CB alone. The wire is no longer a simple potential divider of two equal halves; the lower half’s resistance is lowered by the ammeter in parallel, and it gets less than half the 1.5 V. (The points fit a wire of resistance 5.0 Ω: with C at the middle, 2.5 Ω in parallel with 5.0 Ω is 1.67 Ω, in series with 2.5 Ω, which gives 1.5×1.674.17=0.60 1.5 \times \frac{1.67}{4.17} = 0.60 V.)