Skip to content

← Grade 12 Physics

Exam practice

Every question from the end of every unit, with hints and answers to open. After you check an answer, mark how you did, and come back to the ones you didn’t get.

4 questions

Unit 17 · Magnetic Properties of Materials

Answer these questions

13.
  • a.A ferromagnetic substance becomes paramagnetic above its Curie temperature. Explain why.
  • b.The magnetic intensity at a point is 1000 A/m. Find the magnetic induction in a material of magnetic susceptibility 1272 placed there.
Hint

b. B=μ0(1+χ)H B = \mu_0(1 + \chi)H .

Answer
  • a.A ferromagnet is magnetic because its atomic magnets line up together in domains, held in line by the strong exchange interaction between neighbors. Heat makes the atoms jiggle, which works against the lining up. Above the Curie temperature the jiggling wins: the atomic magnets point every way, the domains break up, and only a weak lining up remains when a field is applied, as in a paramagnet. So the substance becomes paramagnetic, with χ=C/(T−TC) \chi = C/(T - T_C) . Cooled below the Curie temperature, the domains form again.
  • b.H = 1000 A/m, χ = 1272.

B=μ0(1+χ)H=4π×10−7×1273×1000=1.6 T B = \mu_0(1 + \chi)H = 4\pi \times 10^{-7} \times 1273 \times 1000 = \mathbf{1.6\ T}

14.
  • a.Define relative permeability and magnetic susceptibility.
  • b.Establish the relation between magnetic susceptibility and relative permeability.
  • c.What properties should a substance have to make a permanent magnet?
Hint

b. Start from B=μ0(H+I) B = \mu_0(H + I) and put I=χH I = \chi H .

Answer
  • a.The relative permeability μr of a material is the ratio of its permeability to the permeability of a vacuum, μr=μ/μ0 \mu_r = \mu/\mu_0 , where μ = B/H: how many times larger B is in the material than in a vacuum for the same H. It has no unit. The magnetic susceptibility χ is the ratio of the intensity of magnetization to the magnetizing field, χ=I/H \chi = I/H : how easily the material is magnetized. It has no unit.
  • b.The induction in a material is B=μ0(H+I) B = \mu_0(H + I) . Since I=χH I = \chi H ,

B=μ0(H+χH)=μ0H(1+χ) B = \mu_0(H + \chi H) = \mu_0 H(1 + \chi)
Dividing by H, μ=B/H=μ0(1+χ) \mu = B/H = \mu_0(1 + \chi) , and dividing by μ₀,
μr=1+χ \mu_r = 1 + \chi
c. It should be ferromagnetic, with a high coercivity, so that stray fields, knocks and handling don’t demagnetize it, and a high retentivity, so that it stays strongly magnetized: a wide hysteresis loop, like that of steel or alnico. A high Curie temperature helps too, so that it keeps its magnetism when warm.

15.
  • a.Define retentivity and coercivity.
  • b.Two hysteresis loops, a and b, are shown in Figure 17.18.
  • i.Which best represents the hysteresis loop of soft iron? Give a reason for your answer.
  • ii.Which material, a or b, is more suitable for a transformer core, and which for a permanent magnet? Justify your answer.
  • iii.Name the physical quantity represented by the area of the hysteresis loop.
BH(a)BH(b)
Figure 17.18 For question 15: two hysteresis loops, a, wide, and b, narrow.
Hint

Soft iron is easy to magnetize and to demagnetize.

Answer
  • a.Retentivity is the magnetic induction left in a material when the magnetizing field is reduced to zero (Ob in Figure 17.13). Coercivity is the reverse magnetizing field needed to bring the magnetic induction in the material to zero (Oc).
  • b.i. b: its loop is narrow, so a very small reverse field brings B to zero. Soft iron has a low coercivity, and its loop has a small area.
  • ii.b for the transformer core: the core is taken round its loop 50 times a second, and the narrow loop’s small area means little energy lost as heat, while its low coercivity lets it follow the changing field easily. a for the permanent magnet: its high coercivity means it is hard to demagnetize, and it keeps a large B when the field is removed. Its large loop area does not matter, since a permanent magnet is not taken round its loop.
  • iii.The area of the loop is the energy lost (as heat) per unit volume of the material in one cycle of magnetization, the hysteresis loss.
16.
  • a.i. Define magnetic hysteresis. Sketch and label a typical hysteresis loop for a ferromagnetic material.
  • ii.Explain the significance of the following with reference to the hysteresis loop: 1. retentivity, 2. coercivity, 3. hysteresis loss.
  • iii.How are these properties used in choosing materials for permanent magnets and transformer cores?
  • b.i. Distinguish between diamagnetic, paramagnetic and ferromagnetic materials on the basis of 1. their magnetic susceptibility, 2. their behavior in an external magnetic field, 3. examples.
  • ii.Explain why ferromagnetic materials show hysteresis but diamagnetic and paramagnetic materials do not. Use the idea of magnetic domains in your explanation.
Hint

a. i. Draw B against H: the first magnetization curve to saturation, then the loop, and mark the retentivity and coercivity on the axes.

Answer
  • a.i. Magnetic hysteresis is the lagging of the magnetic induction B behind the magnetizing field H when H is taken through a cycle. The loop is drawn as in Figure 17.13: B against H, the first magnetization curve O to a (saturation), then a → b (H = 0, B = Ob, the retentivity) → c (B = 0, H = −Oc, the coercivity) → d (saturation the other way) → e → f → a.
  • ii.1. Retentivity (Ob) shows how much magnetism the material keeps when the field is removed. 2. Coercivity (Oc) shows how large a reverse field is needed to demagnetize it: how firmly it holds its magnetism. 3. Hysteresis loss, the area of the loop, is the energy wasted as heat in each unit volume in every cycle of magnetization.
  • iii.A permanent magnet needs a high retentivity and, above all, a high coercivity, so that it stays magnetized: a wide loop (steel, alnico, neodymium–iron–boron). Its loss doesn’t matter, since it isn’t cycled. A transformer core is cycled 50 times a second, so it needs a small loop area (little heat) and a low coercivity, with a high permeability: a narrow loop (soft iron, silicon steel).
  • b.i.
Diamagnetic Paramagnetic Ferromagnetic
1.Susceptibility small and negative (about −10⁻⁵) small and positive (about 10⁻⁵ to 10⁻³) large and positive (hundreds to thousands)
2.In a field magnetized feebly against the field; weakly repelled, moves towards weaker field; a rod sets across the field magnetized feebly along the field; weakly attracted, moves towards stronger field; a rod sets along the field magnetized strongly along the field; strongly attracted; keeps some magnetism when the field is removed
3.Examples bismuth, copper, water aluminium, platinum, oxygen iron, cobalt, nickel

ii. A ferromagnet is made of domains, each magnetized to saturation. When it is magnetized, the domain walls move and the domains turn; but the walls catch on impurities and flaws in the crystal and jump past them, so the changes are not reversible. When the field is reduced, the walls do not all move back, and some magnetization remains (retentivity); a reverse field is needed to undo it (coercivity). So B on the way down differs from B on the way up: a loop. Diamagnetic and paramagnetic materials have no domains: each atom responds to the field by itself, at once, and the response disappears completely when the field is removed. Their magnetization is always proportional to H, a single straight line through the origin, with no loop.